Air Shower Room

An Air Shower Room is a controlled entry chamber installed between a non-clean area and a cleanroom. It uses high-velocity, HEPA- or ULPA-filtered air jets to blow loose dust, fibers, hair, and particles off personnel, garments, or materials before they enter the controlled environment.

How it works

  1. The person or trolley enters through the “dirty-side” door.

  2. Both doors are electrically interlocked, so the clean-side door cannot open until the shower cycle finishes—helping preserve cleanroom pressure and reduce cross-contamination.

  3. Adjustable nozzles discharge filtered air at roughly 20–25 m/s across clothing and surfaces.

  4. Particle-laden air returns through floor/side grilles, passes through pre-filters and HEPA filtration, and is recirculated.

  5. Typical personnel cycles last 15–30 seconds; cargo showers may run 30–60 seconds.

Typical construction

  • Body: Modular stainless steel (often SS 304) or powder-coated steel panels.

  • Doors: Hinged or automatic sliding; single- or double-door configurations.

  • Filtration: Pre-filter plus HEPA filter, commonly rated around 99.95–99.99% efficiency at 0.3 µm.

  • Controls: PLC/microprocessor control, LED display, adjustable shower time, infrared/automatic activation, voice prompts, and door interlocking.
  • Nozzle layout: Side-wall and sometimes ceiling nozzles; single-side, double-side, or three-side blowing options.

  • Where it is used

Air shower rooms are common in pharmaceutical plants, biotechnology facilities, electronics and semiconductor manufacturing, laboratories, medical-device production, food processing, and other ISO-classified cleanroom operations.