A fume hood provides safe ventilation to protect against exposure to hazardous or toxic fumes, vapours, or airborne particulate. A chemical fume hood is primarily used in manufacturing applications to protect the user or environment outside the hood, but can also be used to protect the materials or experiment under the hood. Ducted fume hood design connects to a remote exhaust system to safely ventilate outside the building.Industrial Ductless fume hood configurations filter and recirculate purified air via a built-in blower and filtration system.

Chemical fume hood add-ons include activated carbon filters for removal of non-hazardous, nuisance odours. HEPA or ULPA filters can also be added to a light duty fume hood to remove microscopic dust and microbes. Explosion-proof fume hood configurations are available for volatile or combustible applications. A wall-mount canopy fume hood provides additional flexibility when floor space is limited.

Specifications

Construction Galvanized Iron Powder Coated, Stainless Steel, Polypropylene.
Type Floor Standing Model / Table Top Model
Face Velocity 90 - 100 FPM /0.5 Mts. Per. Sec. (Average At 12" Sash Opening Fume Hood)
Air Volume 1000 CFM (Designed For Full Door Opening)
Air Flow type Standard
Cabinet Electro Galvanised Sheet With Epoxy Powder Coat Finish / Stainless Steel / Polypropylene With Smooth Finish.
Bottom Arrangements Cabinets, With Cupboard With One Horizontal Partition And Shutters. Cupboards Will Be Provided With Branded Locking Arrangements And Aesthetic Handles Finished With Epoxy Powder Coating.
Baffles Aerodynamic Shape Fully Made Of 3mm FRP.
Work Top Easy To Clean And Chemical And Heat Resistant Black Granite 18mm.
Sash (Shutter) Single, Vertical Sliding, Concealed Type Door. Balanced With Counter Weight, Sash Weights, Wire Etc., Provided With 5mm Thick Glass Window With Steel Frame.
Blower Type Blower Type
Powered by 1 HP 1440 RPM Single Phase.  Blower Is Sufficient For Maximum Distance Of 10 Mtrs. For Requirement More Than 10 Meters 3 HP Capacity Blower Is Required At Extra Cost.
Coupling Direct
Balancing Dynamically Balanced
Air Volume 1000 CFM
Static Pressure 2' W.G.
Casing Casing With FRP Lining
Impeller Fully Moulded PP Impeller
Exhaust Duct PVC/FRP Duct Pipe Of 200 mm Dia With Suitable Elbow For A Length Of 2 Meters, Will Be Supplied With The System. Will Include Exhaust Chimney With Weather Cowl, Bends Flanges, Brackets Etc. Additional Length Of Ducting Will Be Supplied At Extra Cost.
Electrical Arrangements 2 Nos. 15/5 Amps 3 Pin Socket Cum Control Switch.
1 No. Switch Button For Blower, 1 No. Illumination Switch. 1 No. Indicating Lamp.
Illumination By 4 Feet Tube Light.
Sink & Tap

Sink With Outlet Nipple Single Way / Three Way Swan Neck Tap Will Be Provided.

Fume Hood Frequently Asked Questions

Selecting the appropriate fume hood or ductless exhaust hood, ensuring operator protection, and maintaining optimum hood performance can be a monumental task. Asking the right questions will help drive your decision-making process toward the right system for your application and support your standard operating procedures in maintaining a safe environment.

Does my work require a fume hood?

Use of a chemical fume hood is required to enclose work involving toxic gasses, reactive or explosive materials, volatile chemicals, carcinogens, flammable chemicals, hazardous substances and processes producing aerosols or nuisance odours.

What’s the difference between a ducted fume hood and a ductless exhaust hood?

Exhaust fume hoods vent air from the work area directly outside of the building by connecting to the facility’s ducted exhaust system. Ductless exhaust, or stand-alone, fume hoods use integral blowers to draw air away from the work area through a set of filters before safely releasing the air back into the ambient lab. Ductless hoods commonly use a two-stage filtration system composed of a charcoal filter for vapour containment and a final HEPA Filter for particle containment. Charcoal filters capture chemical vapours with varying degrees of efficiency; review your list of chemicals - along with solvent concentrations and aliquoted volumes - with your fume hood specialist to ensure the appropriate filter is purchased. Fume hoods are required to safely enclose chemicals, such as methanol, that are not captured efficiently by charcoal filtration. Small-footprint ductless fume hoods fit onto crowded benchtops or into areas of the lab without access to the facility exhaust system. The effectiveness of a ductless exhaust hood is contingent upon regular filter maintenance.

 

Although the primary purpose of a Fume hood is operator safety, demand has increased for hoods designed to carry lower operating costs and reduced environmental impact. As fume hoods consume an average of 70,000 cubic feet of pre-conditioned air per hour, their operating costs are tied primarily to their air consumption, cited as volumetric rate (CFM) or face velocity (fpm). High-performance fume hoods - also called green ventilation hoods, high efficiency hoods or low-flow hoods – provide the highest level of containment at the lowest operating cost. High-performance fume hoods are designed to safely operate while maintaining a face velocity of 60 fpm, the lowest acceptable ASHRAE performance standard as outlined by SEFA. In addition to reduced face velocities, high efficiency fume hoods can integrate with Variable Air Volume (VAV) building automation systems to ensure minimum allowable room air changes, safe room pressurization and desirable temperature and humidity set points. A conventional light-duty, or by-pass, fume hood carries a lower up-front cost than a high-performance hood, but does not include design features allowing for reduced air volume ventilation or VAV integration. Most light-duty exhaust hoods safely operate at face velocities between 90 – 110 fpm, equal to an increase in air consumption of 30 – 50% annually. To decide between a light-duty chemical hood and a high-performance fume hood, a life cycle cost analysis is required to compare energy cost, ambient climate conditions and usage rate.

 

Does my work require a Bench top fume hood, walk-in hood or canopy hood?

Bench top fume hoods are mounted on an existing work surface, or casework, to create a negative-pressure environment for fume containment. A walk in Fume Hood, or floor-mounted hood, includes no work surface or cabinetry, allowing the user to place large items into the hood at floor level. A Canopy Fume Hood is installed on the wall or suspended from the ceiling; it does not include a hood frame or physical barrier between the fume hood area and the ambient lab. Benchtop fume hoods are designed to enclose singular processes on a crowded benchtop, like small-scale solvent evaporation or ethanol extraction. Walk-in fume hoods can accommodate bulk storage systems, like 50-gallon drums, large processing equipment and heavy items transported by lab carts. Canopy exhaust hoods are designed to vent non-toxic materials like heat, steam and nuisance odours emanating from ovens, steam baths or autoclaves.

 

Should I purchase a remote blower or dedicated, built-in blower with my lab fume hood?

Built-in blowers, or exhaust fans, are installed within the body of the fume hood and positioned above the work area. Remote exhaust blowers are installed on the building exterior and connect to the fume hood through a duct system. Built-in blowers are easier to install and less expensive, but can be noisy. As integral, built-in blowers can place sections of the ductwork under positive pressure, thus pushing contaminants through duct leaks back into the lab, they are recommended for non-hazardous applications, short duct runs, or mobile labs. Remote blowers, though more expensive and complex to install, can be sized for the specific situation, taking into account the duct diameter and run length and quantity of 90-degree or 45-degree elbow turns. Remote blowers keep the ductwork under constant negative pressure; any leaks in the duct system will draw air into the duct for exhaust from the building. Remote blowers include exhaust stacks and zero-pressure weather caps, ensuring the exhausted air is terminated at least 10 feet above the roofline to prevent fumes from returning to the building through the HVAC system.

Which blower should I choose for a ducted fume hood?

To maintain the safety and containment of your Fume hood, selecting the proper motor blower is critical. Exhaust blowers are composed of three materials: steel, fiberglass and polyvinyl chloride (PVC). Review your chemical list with your fume hood specialist; steel blowers are designed for low-to-moderate corrosives, fiberglass blowers resist harsh solvent and acids, and PVC blowers can withstand exposure to high corrosives, such as per chloric acid. To determine the proper blower size, or capacity, you must calculate your fume hood resistance, measured is static pressure loss. Fume hood resistance is calculated by accounting for hood face velocity, volumetric rate and static pressure along with exhaust duct diameter, number of duct turns, operating temperature, and facility altitude. Talk to your hood specialist to calculate your hood resistance and determine an appropriate blower size. Most blowers can safely maintain airflow between 250 – 3,500 CFM.

 

If I’m working with flammable chemicals, do I need an explosion-proof hood?

Not necessarily. All fume hood electrical components are mounted on the corner posts, outside of the flammable vapour trail. Additionally, air constantly exhausting through the work area continually dilutes the air inside the fume hood, creating conditions under which few chemicals reach their lower explosive or flammability limits, according to the NFPA (National Fire Protection Association). Explosion-proof fume hoods are required if a flammable chemical’s concentration exceeds 25% of the LEL (Lower Explosion Limit) or LFL (Lower Flammability Limit). Talk to your fume hood specialist to calculate your dilution factor and volumetric air flow rate, along with each chemical’s LEL and LFL, to determine if an explosion-proof hood is required.

How do you organize the work area inside a fume hood?

In general, the work area should only contain supplies and reagents dedicated to on-going experiments. If you must store equipment - such as balances, centrifuges, hot plates or rotary evaporators - inside the fume hood, please ensure the equipment is located away from the rear air baffles and elevated at least 2” off the work surface. Any equipment, sample racks, or consumables positioned downstream of an experiment may block contaminants from safe exhaust, reducing the effectiveness of the fume hood. All open chemicals must be placed at least 6 inches from the front edge of the fume hood air foil to prevent eddy currents from pushing the vapours through the front of the hood face.

How can I reduce eddy currents in my work zone?

Eddy currents are sporadic, turbulent airflow patterns generated by disruptions inside the work area or at the hood face. Limiting eddy currents are vital to maintaining containment and operator protection. Keep lab doors and windows closed to prevent extra sources of air from sweeping across the hood face. Restrict personnel traffic near the hood when the shield is raised to prevent cross-drafts. Electrical cords, gas hoses or water lines running into the hood must be inserted underneath the air foil or through petcock connections to ensure the hood shield closes properly.