Thu May 26, 2022
Industrial air shower
1 | Dimensions | WxDxH : 900x1000x2000 mm (Inner Area) WxDxH: 1400x1075x2150 mm (Outer Area) Or Customized |
2 | MOC | Galvanized Iron Powder Coated / Stainless Steel 304 |
3 | Blower Assembly |
Dynamically And Statically Balanced Motors And Blowers
|
4 | Motor | Make Eyaani |
5 | Nozzles | Made Of Stainless Steel Rotating And Adjustable Fixed Either Side Of Wall And Top Ceiling Velocity 70 Meters/Sec |
6 | Blower CFM | 25-30 Meters/sec |
7 | Face Velocity | 20-22 meters/sec (3937-4330 FPM) |
8 | Air Flow | 20-22 meters/sec (3937-4330) |
9 | Class | 10000 |
10 | Interlocking of doors | Interlocking Facility of doors,One door lock Automatically when other is opened with electromagnetic lock,with timer setting |
Air Shower is a self contained well built factory assembled designed to deliver a spray of moving air from nozzles transported and virtually can be installed at any site. Absolute filter-fan module provide positive pressurization and filtration down to 99.97% efficiency on 0.3 micron. The Clean Air inside the Shower will support a very high degree of sterility and clean air condition.The system is supplied with optionally aluminium grated floor located approximately 6 inches above datum level. Duct air chassis are installed within the walls of the units. While the system is in operation, both doors will be automatically locked. In the event of power failure or an emergency, the doors get unlocked. Construction is of Mild Steel Powder coated / Stainless Steel 304 grade. Provided with two aluminium framed acrylic / glass door with automatic locking device. Statically/dynamically balanced, blower draws the air through pre-filters and throws it through HEPA filter into the chamber. Suitable to work on 220V, 1 phase 50 Hz, AC supply
Accumax India Air Shower Protects Your Clean Room Environment From Unwanted Contamination. Clean Garments Become Contaminated During The Gowning / Ungowning Process, And Because Of High Traffic In The Gowning Area. The Contamination Problem Is Amplified When The Same Garment Is Worn Several Times Or Is Taken On And Off Numerous Times During The Day. Air Shower Is An Effective Method Of Removing This Surface Contamination. Otherwise Contamination Will Be Carried Directly To Clean Room And Deposited On Products And Clean Areas By Coming Off The Surface Of The Garments. The Air Shower Is Constructed Of Galvanized Iron Powder Coated / Stainless Steel. The Units Provide Air Flow Of Through Adjustable Nozzles Of Stainless Steel. The Unit Can Be Shipped Knocked Down Or Completely Assembled. All Parts Will Fit Through A Standard Door In Knock Down Conditions. Service To The Blower Motor And Filters Is Carried From Inside The Air Shower Or From The Top.
Air Shower Is A High Velocity, Low Pressure Type System, Providing A Normal Entrance To And Exit From A Contamination Controlled Area. Air Showers Supply Concentrated HEPA Filtered Air In High Velocity Jets That Lift Off Contamination While An Individual Stands In Or Walks Through, The Specially Constructed Air Chamber. When The Unit Is Activated, Pressurised Filtered Air Streams From Adjustable Nozzles. The Nozzles Are Arranged On Walls And Ceilings In A Uniform Pattern To Ensure Effective Distribution Of Filtered Air. The Closed Loop Circulation Design Directs Contaminated Air Downward Through Grills And Hollow Walls Of The Air Shower And Back To The Filter, Which Removes 99.99% Of All Particles Down To 0.3 Microns.