ID : A0012
Description
BIOHAZARD SAFETY CABINET Type A-2, Class II
Bio Safety Cabinet Class II Also has An Open Front Design Provided With Negative Pressure Generation Module. This Equipment Provides Recirculation Of Mass Flow Of HEPA Filtered Air. This Type Of Bio Safety Cabinets Provides Excellent Protection To Users, Products And The Environment.
Construction
Bio Safety Cabinet Is Designed To Conform To The United State Federal Standard 209B/BS5295 And Meets The Class 100 Conditions Along With British Standard 5726-Appendix A. Our Units Are Fabricated Of Galvanized Iron Powder Coated/ Stainless Steel. The Side Panels Made Out Of Heavy Plexi Glass Sheets Are Mounted On Anodized Aluminum Frames. The Whole Unit Is Supplied With Manometer To Gauge The Pressure Drop In The Unit While Operation, Beside The Gas Cock, Power Socket Etc
Filter Assembly
Fitted With Fully Washable Synthetic Pre-Filter Units And Secondary High Efficiency Perfect Air Filters Made Of Mini Pleated Non Woven Fabric. The Efficiency Of Our Filters Have A Rating Better Than 99.99% At DOP (Cold) And 99.97% At DOP (Hot). Our Units Have The Capacity To Hold All Suspended Particles Of Size > 0.3 Micron.
Motor And Blower Assembly:
Provided With Perfectly Balanced (Static As Well As Dynamic) Motor And Blower
Illumination:
Illumination At The Work Table By Means Of LED Lights Panel Concealed At The Upper Portion Of The Unit.
Ultra Violet Light Is Incorporated In The Illumination Panel Of Our Bio Safety Cabinets To Take Care Of The Sterilization Of The Existing Air Present In The Enclosure, Thus Ensuring The High Standard Of Cleanliness In Our Equipment Before The Commencement Of Actual Working.
Noise Level:
Our Bio Safety Is Designed To Ensure That The Work Enclosure Has Minimum Possible Vibration Levels And Noise Level Is Also Contained Below 70 db.
Biosafety cabinet class ii, type a2 specification:
Cleanliness |
Class 100 |
Velocity |
90 Feet / Min±20 |
Noise Level |
65 Decibels ± 5% On A Scale |
Particle Retention |
0.1 Micron |
Efficiency |
99.999 % |
Pressure Drop |
23 mm Wg |
Size-At Exhaust |
6”x 6” x 6” |
Pre-Filter |
Non Woven-Synthetic Polyester |
Particle Retention |
10 -15 Micron |
Efficiency |
90% |
Pressure Drop |
6 mm Wg |
Blower Assembly |
By 1 No ¼ Hp, Single Phase, 1440 RPM Motor, Directly Coupled With A Pair Of Aluminum Centrifugal Impeller. |
Exhaust Assembly |
By Motor of ¼ HP, Single Phase,1440 RPM Motor, Directly Coupled With A Aluminum |
Ultra Violet Lamp |
Philips/Osram Make |
Illumination |
LED |
Standard Accessories |
Pressure Manometer, Additional Power Point Gas Inlet Nozzle, And Floor Levelling Screws, Wire Cord |
Power Supply |
220 V, Single Phase, 50 Hz |
Working Area |
W 900 x D 600 x H 600mm W 1800 x D 600 x H 600mm |
Market we cover
We are a leading Biosafety cabinet manufacturers in India. Having factory based in Delhi, the company has been manufacturing customized Biosafety Cabinets Class II Type A2 and sell them at reasonable price throughout India and overseas market including African and Middle East countries. We have technicians, machinery and knowledge that makes us capable to serve you with your choice of Biosafety cabinet that may vary in dimensions, associated accessories and control points etc. Made of branded parts, these cabinets are highly effective to maintain maximum level of safety; hence, considered a necessary part of any research purpose.
International Market Cover
Saudi Arabia, Kuwait, Qatar, Oman, Iraq, Baharain, UAE, Malaysia.
Indian Market Cover
Maharashtra, Gujarat, Bangalore, Chennai, Coimbatore, Baddi, Rudrapur, Haridwar, Roorkee, Orrisa, Haryana, Manipur, Andhra Pradesh, Assam, Sikkim, Rajasthan, Meghalaya, Tripura, Tamil Nadu, Arunachal Pradesh, Karnataka, Bihar, Goa, Chhattisgarh, Mizoram, , Nagaland, Jharkhand, Jammu and Kashmir, Uttar Pradesh, West Bengal, Kerala, Punjab, Uttarakhand, Orissa, Madhya Pradesh, etc.